Whether for borehole monitoring or ROV, stream gauging or harbour water levels – these instruments are trivial to install and operate. The units are completely sealed and are available rated up to 10,000dbar. Attach a 6 pin MCIL-6-FS connector with serial and power connectors and the data will stream. Serial baud and sampling rates are user-configurable.
RBR's designs lead the industry in accuracy, stability, and power consumption. For other parameters, RBR source sensors from around the industry and integrate them tightly onto their loggers, including deep understanding of ranging behaviour, settling time, and dynamic effects.
Internal calibration coefficients and a full data processing system result in streaming engineering unit data.
Serial baud and sampling rates are user-configurable.
Electrical
- External Power: Requires 6-18V, ~3mA
- Communication: RS-232 output
- Data: Polled or autonomous streaming
- Baud Rate: 1200 to 115k
- Connector: MCBH-6MP
ElectricalDimension / Weight (air / water)
RBRcoda3T | deep | 305 mm | ~295gr / ~176gr |
RBRcoda3D | deep | 275 mm | ~315gr / ~196gr |
RBRcoda3T.D | deep | 335 mm | ~350gr / ~216gr |
- Calibrated measurement range: -5°C to 35°C
- Initial accuracy: ±0.002°C
- Resolution: <0.00005°C
- Time constant: ~1s (standard) or ~0.1s (optional)
- Typical stability: 0.002°C/year
- Dimensions: 265mm x ø25mm
- Weight (air/water): 132g/~3g
- Maximum Depth: 10,000m
- Calibrated measurement range: Plastic: 20 / 50 / 100 / 200 / 500 / 1000 dbar
- Calibrated measurement range: Ti: 1000/ 2000 / 4000 / 6000 / 10,000 dbar
- Initial accuracy: ±0.05% full scale
- Resolution: <0.001% full scale
- Dimensions: 235mm x ø25mm
- Weight (air/water): 132g/~3g
- Maximum Depth: 10,000m
- Calibrated measurement range: Plastic: 20 / 50 / 100 / 200 / 500 / 1000 dbar
- Calibrated measurement range: Ti: 1000/ 2000 / 4000 / 6000 / 10,000 dbar
- Initial accuracy: ±0.05% full scale
- Resolution: <0.001% full scale
- Dimensions: 295mm x ø25mm
- Weight (air/water): 152g/~17g
- Maximum Depth: 10,000m
- Calibrated measurement range: As for pressure
- Burst length: Up to 16384 readings
- Sampling rate: Up to 16Hz
- Dimensions: 235mm x ø25mm
- Weight (air/water): 132g/~15g
- Range: 0-500 μM (saturation 0 – 120%)
- Initial accuracy: Maximum of ±8μM or ±5%
- Resolution: <1μM (saturation 0.4%)
- Sampling Rate: 24hr to 1Hz
- Dimensions: 116mm x ø28mm
- Weight (air): 170g
- Maximum Depth: 6000m
- Range: 400nm to 700nm
- Initial accuracy: ±2%
- Wavelength: 400-700nm
- Sampling Rate: 16Hz or slower
- Dimensions: 265mm x ø25mm
- Weight (air): ~120g
- Maximum Depth: 560m